Bently Nevada 1900/25 Conditioning Vibration Monitor.The Bently Nevada 1900/25 is a single-channel, stand-alone, locally mounted vibration monitor.14 The unit is designed to provide mechanical protection for all or selected seismic vibration points on the Trendmaster 2000 system. However, it can also operate independently as a stand-alone mechanical protection device, making it suitable for general purpose or critical machinery.
The 1900/25 accepts a single sensor input from a compatible Trendmaster 2000 accelerometer, conditioning the signal to peak velocity units and
providing a local display and status indication. It also provides an alarm relay contact output for connection to an external signaller.
1900/25 This unit has an input sensitivity of 100 mv/g and a maximum acceleration of 20 g peak. It can handle a maximum differential input voltage
of 4 volts peak to peak. Power requirements are AC: 85 to 264 Vac or DC: 110 to 370 Vdc with a current draw of 60 mA typical, 120 mA maximum.
For more products, click here For more offers contact plcdcs-module@foxmail.com
This article is from the official website of Xiamen Xiongba, please include the following link for reproduction:www.plcdcsmodule.com | Bently Nevada 1900/25 Conditioning Vibration Monitor